超声辅助萃取气相色谱-质谱法测定松针中的多溴联苯醚

陈长二,赵洪霞,谢晴,陈景文*   

  1. Key Laboratory of Industrial Ecology and Environmental Engineering of Ministry of Education, Department of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
  • 收稿日期:2008-09-02 修回日期:2008-11-20 出版日期:2009-01-30 发布日期:1983-03-25
  • 通讯作者: 陈景文
  • 基金资助:
    国家重点基础研究计划(“973”计划)课题(2006CB403302).

Determination of polybrominated diphenyl ethers in pine needles using ultrasonic-assisted extraction and gas chromatography-negative chemical ionization-mass spectrometry

CHEN Chang’er, ZHAO Hongxia, XIE Qing, CHEN Jingwen*   

  1. Key Laboratory of Industrial Ecology and Environmental Engineering of Ministry of Education, Department of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
  • Received:2008-09-02 Revised:2008-11-20 Online:2009-01-30 Published:1983-03-25
  • Contact: CHEN Jingwen

摘要: 建立了测定松针样品中多溴联苯醚(PBDEs)的分析方法。松针样品经过正己烷-丙酮(体积比为1∶1)混合溶液超声萃取、浓硫酸和氧化铝柱净化后,采用气相色谱-负化学电离源质谱(GC-NCI-MS)选择离子监测(SIM)模式检测,内标法定量。结果表明,方法的加标回收率为83.8%~107.5%,三溴~七溴代联苯醚的仪器检出限为0.152~ 0.770 pg,十溴代联苯醚(BDE-209)的检出限为11.1 pg;三溴~七溴代联苯醚的方法检出限(湿重)为3~15 pg/g,BDE-209的方法检出限(湿重)为222 pg/g。方法具有良好的重现性、较高的灵敏度和良好的回收率。实际样品分析表明,松针中BDE-209是主要的同类物,约占8种PBDEs总量的82.3%,低溴代联苯醚以2,2′,4,4′-四溴联苯醚(BDE-47)为主。

关键词: 超声辅助萃取, 多溴联苯醚, 气相色谱-负化学电离源质谱, 松针

Abstract: A method for the determination of polybrominated diphenyl ethers (PBDEs) in pine needles was developed. Ultrasonic-assisted extraction (UAE) was employed with n-hexane-acetone (1∶1, v/v), and concentrated H2SO4 and an alumina column were used for cleaning-up the extract of pine needles. The final extract was identified and quantified for the 8 PBDE congeners(BDE-28, 47, 99, 100, 153, 154, 183, and 209) by gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS) with internal standard method in the selective ion monitoring (SIM) mode. The recoveries of the spiked standards ranged from 83.8% to 107.5%. The instrumental detection limits for tri- to hepta-BDEs (BDE-28, 47, 99, 100, 153, 154 and 183) were in the range of 0.152-0.770 pg, and for BDE-209 was 11.1 pg. The method detection limits for the above-mentioned PBDEs were 3-15 pg/g wet weight and 222 pg/g wet weight, respectively. The results indicate that the method has high sensitivity, satisfactory recovery and good reproducibility. BDE-209 was found to be the dominant congener (82.3% of the total of 8 PBDEs), and BDE-47 was the major congener among the lower brominated congeners.

Key words: polybrominated diphenyl ethers (PBDEs), gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS), pine needles , ultrasonic-assisted extraction (UAE)