色谱 ›› 2025, Vol. 43 ›› Issue (11): 1244-1251.DOI: 10.3724/SP.J.1123.2024.12030

• 研究论文 • 上一篇    下一篇

超高效液相色谱-串联质谱法定量测定低致敏婴幼儿配方乳粉中牛乳过敏原

徐道坤1,2, 杨洋3, 黄浩伦1, 孙小杰1,2, 胡文彦1,2, 刘新梅1,2, 杨军1,2,*()   

  1. 1.南京市食品药品监督检验院,江苏 南京 211198
    2.江苏省市场监管局重点实验室(食品真实性鉴别技术),江苏 南京 211198
    3.东部战区空军医院普外科,江苏 南京 210001
  • 收稿日期:2025-01-03 出版日期:2025-11-08 发布日期:2025-11-07
  • 通讯作者: *E-mail:yangjun711003@163.com.
  • 基金资助:
    江苏省市场监管局科技计划项目(KJ2022076)

Quantitation of cow’s milk allergen in hypoallergenic infant formulas using ultra-high performance liquid chromatography- tandem mass spectrometry

XU Daokun1,2, YANG Yang3, HUANG Haolun1, SUN Xiaojie1,2, HU Wenyan1,2, LIU Xinmei1,2, YANG Jun1,2,*()   

  1. 1. Nanjing Institute for Food and Drug Control,Nanjing 211198,China
    2. Key Laboratory for Food Authenticity Identification Technology of Jiangsu Provincial Market Regulation Administration,Nanjing 211198,China
    3. The Air Force Hospital from Eastern Theater Command,Nanjing 210001,China
  • Received:2025-01-03 Online:2025-11-08 Published:2025-11-07
  • Supported by:
    Science and Technology Program of Jiangsu Provincial Market Regulation Administration(KJ2022076)

摘要:

本研究以低致敏婴幼儿配方乳粉为研究对象,结合抗原表位特征序列和质谱响应,对先前挖掘的18条表征牛乳过敏蛋白的特征多肽进一步筛选,得到6条定量多肽。随后建立了同时定量测定低致敏婴幼儿配方乳粉中6种牛乳致敏蛋白(α-乳白蛋白、β-乳球蛋白、αS1-酪蛋白、αS2-酪蛋白、β-酪蛋白及κ-酪蛋白)的超高效液相色谱-串联质谱(UHPLC-MS/MS)分析方法。添加牛乳致敏蛋白标准品的空白低致敏婴幼儿配方乳粉经过蛋白提取、酶解和净化后进行UHPLC-MS/MS分析。根据每种蛋白不同添加浓度和质谱响应建立标准曲线。结果表明:6种牛乳致敏蛋白在0.05~500 mg/kg内线性范围良好,相关系数(r2)均大于0.99,检出限为0.05~5.0 mg/kg,定量限为0.1~10.0 mg/kg,优于文献报道的3种基于质谱和2种基于酶联免疫吸附试验(ELISA)的检测方法。在低、中、高3个添加水平下,6种牛乳致敏蛋白的加标回收率为74.8%~93.4%,日内准确度为-25.09%~-6.09%,日间准确度为-24.0%~-5.41%;日内精密度为1.08%~5.05%,日间精密度为1.35%~4.85%。运用该方法对市售低致敏婴幼儿配方乳粉进行检测,3种部分水解低致敏婴幼儿配方乳粉(pHF)和2种深度水解低致敏婴幼儿配方乳粉(eHF)检出牛乳过敏蛋白,检出量为0.48~27.36 mg/kg。本方法灵敏度好,通量高,可用于低致敏婴幼儿配方乳粉中牛乳过敏原的定量筛查。

关键词: 牛乳过敏原, 超高效液相色谱-串联质谱法, 多肽, 非标定量, 低致敏婴幼儿配方乳粉

Abstract:

Cow’s milk protein allergy (CMPA) has become a common public health concern and hypoallergenic formula (partially or extensively hydrolyzed formula) is considered as an alternative during infancy. Alcalase and papain are widely used in industrial production of hydrolysates, as they can modify or destroy the linear and conformational epitopes of cow’s milk allergens (CMAs), thus leading to decreased allergenicity. However, despite considerable emphasis has been laid on the manufacturing technique and nutritional value of hypoallergenic formulas, whether there are traces of CMAs in hypoallergenic formulas, remains unknown. Consequently, the need for a quantitative method of detecting multiple CMAs at a time is rising. Traditionally, enzyme-linked immunosorbent assay (ELISA)-based methods have proved to be advantageous with a wide availability of commercial kits for CMAs detection. Moreover, polymerase chain reaction (PCR), as one of DNA-based methods, has shown exceptional specificity and high sensitivity. However, they both may encounter false-positive results and high-throughput detection is challenging. In the past two decades, mass spectrometry (MS)-based proteomic technology has advanced, including improvements in computational capability, algorithm model, as well as mass spectrometric platforms. MS is gaining more and more attention in the field of food allergen detection, allowing multiplex allergen detection with high sensitivity, accuracy and selectivity in a single run. In this study, an analytical method was developed for the simultaneous quantitation of six CMAss (namely, α-lactalbumin, β-lactoglobulin, αS1-casein, αS2-casein, β-casein, and κ-casein) in hypoallergenic formulas using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Proteins of spiked hypoallergenic formula were extracted with ammonium bicarbonate and digested with trypsin. After digestion, the samples were purified with a C18 spin column, and analyzed by UHPLC-MS/MS (AB SCIEX Triple Quad 6500+). Separation was achieved on a Waters ACQUITY UPLC Peptide CSH C18 column (150 mm×2.1 mm, 1.7 μm). The mobile phase consisted of 0.1% formic acid aqueous solution and 0.1% formic acid in acetonitrile, and the flow rate was 0.3 mL/min. The sample injection volume was 10 μL, and the column temperature was set to 40 ℃. Mass spectrometer was operated in positive electrospray ionization (ESI+) mode, and multiple reaction monitoring (MRM) mode was adopted. Precursor ions and product ions of marker peptides were predicted by the Skyline software. Mass spectrometric parameters such as declustering potential (DP) and collision energy (CE) were also optimized. Afterwards, by taking allergen epitopes and mass spectrometric responses into consideration, six peptides were retained for quantitative analysis. Calibration curves were constructed with good linearity in the range of 0.05-500 mg/kg, and correlation coefficients (r2) greater than 0.99. The limits of detection (LODs) were 0.05-5.0 mg/kg, and limits of quantification (LOQs) were 0.1-10.0 mg/kg, respectively. The recoveries of the developed method in incurred hypoallergenic formulas ranged from 74.8% to 93.4%. The intraday and interday accuracies ranged from -25.09% to -6.09% and from -24.0% to -5.41%, with precisions between 1.08%-5.05% and 1.35%-4.85%, respectively. Screening of commercial hypoallergenic formula samples confirmed existence of CMAs in three partially hydrolyzed formulas (pHF) and two extensively hydrolyzed formulas (eHF), with contents ranging from 0.48 to 27.36 mg/kg. The analytical method proposed in this study exhibited high sensitivity, high-throughput capability, and can be used to monitor traces of CMAs in hypoallergenic formulas.

Key words: cow’s milk allergens (CMAs), ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), peptides, label-free quantification (LFQ), hypoallergenic infant formula

中图分类号: