色谱

• • 上一篇    下一篇

气相色谱-串联质谱法测定甲油胶中致敏性甲基丙烯酸酯及丙烯酸酯类化合物

梁梓洋#, 梁韵蕊#, 康怀腾, 梁梓豪, 马叶芬, 董钰龙, 罗辉泰*, 黄芳   

  1. 广东省科学院测试分析研究所(中国广州分析测试中心), 广东省化学测量与应急检测技术重点实验室, 广东省中药质量安全工程技术研究中心, 广东 广州 510070
  • 收稿日期:2026-01-24
  • 通讯作者: * Tel:020-88320139,E-mail: luohuitai@qq.com.
  • 作者简介:#共同第一作者.
  • 基金资助:
    广东省科学院发展专项资金项目(2022GDASZH-2022010110); 广东省科学院测试分析研究所(中国广州分析测试中心)2025年度所级科研项目(NACC-SJ202501).

Determination of allergenic methacrylate and acrylate compounds in gel polish by gas chromatography-tandem mass spectrometry

LIANG Ziyang#, LIANG Yunrui#, KANG Huaiteng, LIANG Zihao, MA Yefen, DONG Yulong, LUO Huitai*, HUANG Fang   

  1. Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou), Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Guangdong Provincial Engineering Research Center for Quality and Safety of Traditional Chinese Medicine, Guangzhou 510070, China
  • Received:2026-01-24
  • Supported by:
    Guangdong Academy of Sciences Project of Science and Technology Development (No. 2022GDASZH-2022010110); Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou) Project of Scientific Research in 2025 (No. NACC-SJ202501).

摘要: 甲油胶为近年来新兴起的美甲化妆品,但随着调查与研究的深入,其主要成分之一的(甲基)丙烯酸酯类活性稀释剂已被证明具有安全健康风险,其中2-甲基丙烯酸羟乙酯(HEMA)和三羟甲基丙烷三丙烯酸酯(TMPTA)已被明确列入禁限用名单,然而该类风险物质在我国相关分析方法尚少,存在监管盲区。本研究建立了甲油胶中8种具有致敏性风险的(甲基)丙烯酸酯类化合物((M)AAs)的分析方法。样品经乙酸乙酯溶解后用正庚烷沉淀,冷冻除杂后采用Agilent VF-624ms色谱柱(30 m×0.25 mm×1.40 μm)分离,在电子轰击电离源(EI)下以多反应监测(MRM)检测,基质匹配外标法定量。结果表明,8种目标化合物在0.1~20 μg/mL范围内呈良好线性关系,相关系数(r)均大于0.995 0,方法检出限均为1 μg/g,定量限均为5 μg/g,低、中、高3个加标水平下回收率为87.0%~104.7%,相对标准偏差(RSD)为0.28%~0.94%,稳定性试验下46 h内各化合物峰面积RSD均小于8%。采用本文建立的方法对22批次市售甲油胶进行检测,其中21批次均检出至少1种(M)AAs,已被明确列入禁限用的HEMA和TMPTA检出阳性率分别高达68%和73%,表明甲油胶行业产品仍需要有效的监管以提高安全性与合规性。本方法具有灵敏度高、选择性好、结果准确的优点,可为保障甲油胶产品的安全性与合规性、风险监控和打造我国化妆品高质量发展提供技术支撑,促进该新兴化妆品行业的健康发展。

关键词: 气相色谱-串联质谱法, 甲油胶, 甲基丙烯酸酯, 丙烯酸酯, 化妆品

Abstract: Gel polish is an emerging cosmetic product for nail art, widely popular because of its advantages such as environmental friendliness and ease of application. However, further research has revealed that (meth)acrylates ((M)AAs) based reactive diluents, one of the gel polish’s main components, pose significant health risks. Given the high risk of (M)AAs, 2-hydroxyethyl methacrylate (HEMA) was added to the list of restricted substances in cosmetics by (EU) 2020/1682. Subsequently, trimethylolpropane triacrylate (TMPTA) was included in the list of concerned substances under the California Proposition 65. The aforementioned regulations have made HEMA and TMPTA become the market access red lines. Despite these restrictions, routine laboratory analysis continues to detect HEMA and TMPTA in a considerable proportion of gel polish samples, indicating that safety monitoring remains insufficient. Nevertheless, analytical methods for such risk substances remain scarce in China, leading to regulatory gaps and challenges to meet the demands of high-quality development in the gel polish industry. An analytical method for detecting eight (M)AAs in gel polish was established in this study. These (M)AAs include methyl methacrylate (MMA), 2-hydroxyethyl acrylate (HEA), HEMA, hydroxypropyl methacrylate (HPMA), tetrahydrofurfuryl methacrylate (THFMA), ethylene glycol dimethacrylate (EGDMA), triethylene glycol diacrylate (TEGDA) and TMPTA. Samples were diluted with ethyl acetate and precipitated with n-heptane, followed by freezing to remove interfering impurities such as prepolymers and polymers. In the optimization of solvent type, ethyl acetate was chosen as the diluent for its good solubility for gel polish. n-Heptane, with poor solubility for gel polish, was selected as the precipitant. A volume of 3 mL was chosen as the optimal amount of diluent to achieve good recovery. By examining the freezing time for impurity removal, 10 min was determined as the optimal duration. Chromatographic separation was performed using an Agilent VF-624ms capillary column (30 m × 0.25 mm × 1.40 μm) by GC-MS/MS. In order to improve the sensitivity and specificity of the analysis, multiple reaction monitoring (MRM) was performed using an electron impact ionization (EI) source. Highly characteristic ion pairs were selected based on the mass spectrometry fragmentation patterns, which minimized the matrix interference as much as possible. The eight target compounds exhibited some degree of matrix effects in the gel polish sample. Matrix-matched calibration was used as the quantitative method to eliminate the impact of matrix effects on analytical accuracy. The results showed good linearity for the eight target compounds in the range of 0.1-20 μg/mL, with correlation coefficients (r) all greater than 0.995 0. LOD of the method was 1 μg/g and LOQ was 5 μg/g for all compounds. The recoveries at low, medium, and high spiked levels ranged from 87.0% to 104.7%, demonstrating good accuracy. Excellent precision was achieved, as indicated by the low relative standard deviations (RSDs) between 0.28% and 0.94%. No significant fluctuation in peak areas was observed during the 46 h stability test, as evidenced by RSDs below 8% for all compounds, demonstrating excellent stability. The above validation results indicate that the established method is reliable and suitable for routine analysis. Twenty-two batches of commercially available gel polish were analyzed by the developed method in this study, with at least one (M)AAs detected in 21 batches of samples. Notably, the positive detection rates for HEMA and TMPTA, both explicitly listed as prohibited or restricted substances, reached as high as 68% and 73%, respectively, indicating that effective regulation is still needed for the gel polish industry to improve safety and compliance. This method offers high sensitivity, good selectivity, and accurate results, providing technical support for ensuring the safety and compliance of gel polish products, conducting risk monitoring, promoting high-quality development of cosmetics in China, and fostering the healthy growth of this emerging cosmetic sector.

Key words: gas chromatography-tandem mass spectrometry (GC-MS/MS), gel polish, methacrylate, acrylate, cosmetics