色谱 ›› 2025, Vol. 43 ›› Issue (12): 1354-1363.DOI: 10.3724/SP.J.1123.2025.03014

• 研究论文 • 上一篇    下一篇

超高效液相色谱-串联质谱法测定动物肌肉组织中四环素类抗生素

初坤1, 李金花2, 王倩倩1, 李晓通1, 吴帅1,*(), 陈晨1   

  1. 1.烟台市食品药品检验检测中心,山东 烟台 264000
    2.中国科学院烟台海岸带研究所,山东 烟台 264003
  • 收稿日期:2025-03-13 出版日期:2025-12-08 发布日期:2025-12-08
  • 通讯作者: *E-mail:wushuai97@163.com.
  • 基金资助:
    山东省市场监管系统科技任务项目(2023);国家自然科学基金面上项目(22176210)

Determination of tetracyclines in animal muscle tissues by ultra performance liquid chromatography- tandem mass spectrometry

CHU Kun1, LI Jinhua2, WANG Qianqian1, LI Xiaotong1, WU Shuai1,*(), CHEN Chen1   

  1. 1. Yantai Testing Center for Food and Drug,Yantai 264000,China
    2. Yantai Institute of Coastal Zone Research,Chinese Academy of Sciences,Yantai 264003,China
  • Received:2025-03-13 Online:2025-12-08 Published:2025-12-08
  • Supported by:
    Science and Technology Project of Shandong Province of Market Supervision and Administration (2023);National Natural Science Foundation of China(22176210)

摘要:

四环素类抗生素(tetracyclines, TCs)是一类广谱抗生素,广泛应用于畜禽及水产养殖业。TCs在养殖过程中存在滥用现象,导致其在养殖动物体内残留,对人类健康构成潜在风险。本研究基于超高效液相色谱-串联质谱(UPLC-MS/MS)技术,建立了动物肌肉组织样品(猪肉、鸡肉和鱼肉)中TCs残留量的检测方法,并对样品前处理方法和色谱、质谱条件进行了研究优化。称取2 g均质后的动物肌肉组织样品,加入10 mL含0.2%甲酸的80%乙腈水溶液,振荡提取,低温离心。上清液使用Oasis PRiME HLB固相萃取柱快速一步式除杂净化,净化液经氮气吹干复溶后,进行UPLC-MS/MS分析。待测分析物经Eclipse Plus C18色谱柱(100 mm×2.1 mm,3.5 μm)梯度分离洗脱,在正离子电喷雾(ESI+)、多反应监测(MRM)模式下扫描,采用基质曲线外标法定量。结果表明,TCs在1~500 ng/mL范围内具有良好的线性关系,相关系数(r2)均大于0.994,检出限为0.10~0.15 μg/kg,定量限为0.20~0.50 μg/kg。TCs在低、中、高3个水平(1、5、10 μg/kg)下的平均加标回收率为62.6%~119.0%,相对标准偏差(RSD)为2.0%~9.8%(n=7)。采用本方法检测60份动物肌肉组织样品,TCs的检出率分别为10%、15%和5%。本方法易于操作,具有较高的准确度和精密度,适用于动物肌肉组织中TCs残留量的常规检测。

关键词: 四环素类抗生素, 固相萃取, 超高效液相色谱-串联质谱, 动物肌肉组织

Abstract:

Tetracyclines (TCs) are broad-spectrum antibiotics that are classified as natural or semi-synthetic. Natural TCs include chlortetracycline, tetracycline, and oxytetracycline, while semi-synthetic ones include doxycycline, minocycline, methacycline, and demeclocycline, among others. While TCs are widely used in the livestock, poultry, and aquaculture industries, their indiscriminate use detrimentally affects ecosystems, and residual TCs in animals can adversely affect human health. In this study, we developed an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determining TCs, including minocycline, 4-epioxytetracycline, 4-epitetracycline, oxytetracycline, tetracycline, demeclocycline, 4-epichlortetracycline, chlortetracycline, methacycline, and doxycycline. The developed protocol was used to establish a method for qualitatively and quantitatively analyzing TCs in animal muscle tissue (pork, chicken, and fish meat). To this end, we systematically optimized the mass spectrometry (MS) parameters, solid-phase extraction (SPE) cartridge, and extraction conditions of the method. Animal muscle-tissue samples were homogenized and extracted with 10 mL of 80% acetonitrile aqueous solution containing 0.2% formic acid. How the acetonitrile/formic acid ratio affects the TC-extraction efficiency was investigated using one-way analysis. The supernatant was purified using an Oasis PRiME HLB solid-phase-extraction cartridge, evaporated under flowing nitrogen, and redissolved. Two different C18 UPLC columns were systematically evaluated, and the optimal UPLC conditions were established for the TCs. The Eclipse Plus C18 column (100 mm×2.1 mm, 3.5 μm) was used for separation. The effects of mobile phases A (0.1% formic acid aqueous solution, 5 mmol/L ammonium acetate aqueous solution, and 5 mmol/L ammonium formate aqueous solution) and B (methanol or acetonitrile) on the separation and response values of the TCs were investigated. Optimal response values and peak shapes were obtained using 0.1% formic acid aqueous solution as mobile phase A and 0.1% formic acid acetonitrile solution as mobile phase B, at a flow rate of 0.2 mL/min and a sample injection volume of 5 μL. Gradient elution was performed as follows: 0–2.0 min, 5%B; 2.0–3.5 min, 5%B-15%B; 3.5–7.0 min, 15%B-20%B; 7.0–9.0 min, 20%B-65%B; 9.0–9.1 min, 65%B-90%B; 9.1–10.0 min, 90%B; 10.0–10.1 min, 90%B-5%B; 10.1–12 min, 5%B. The effect of the glass sample bottle on adsorption was also investigated. Both positive- and negative-ion modes were explored in the UPLC-MS/MS experiment to fully scan the parent ions. Positive mode was selected for electrospray ionization (ESI). Two product ions that exhibit strong signals and minimal interference were selected for quantitative and qualitative ion analyses, with quantification performed using the external standard method. Tandem mass spectrometry (MS/MS) was performed in positive electrospray ionization (ESI+) and multiple reaction monitoring (MRM) modes. The following MS/MS parameters were used: capillary voltage, 0.5 kV; cone voltage (CV), 30 V; ion-source temperature, 150 ℃; desolvation temperature, 300 ℃; desolvation gas flow, 800 L/h. Other instrument settings, such as the collision energy (CE) and collision gas flow, were also optimized. The TCs exhibited good linearities within the 1–500 ng/mL mass-concentration range, with all correlation coefficients (r2) above 0.994, and limits of detection and quantification (LODs and LOQs) of 0.10–0.15 and 0.20–0.50 μg/kg, respectively. The target analytes exhibited average recoveries of between 62.6% and 119.0% at three levels (1.0, 5.0, and 10.0 μg/kg), with relative standard deviations (RSDs, n=7) ranging from 2.0% to 9.8%. The developed method was used to determine TCs in 60 animal muscle-tissue samples acquired from a fresh-food supermarket. Tetracycline was detected at a rate of 10% in 20 pork samples, while doxycycline was detected at a rate of 15% in 20 chicken samples, and oxytetracycline was detected at a rate of 5% in 20 fish-meat samples. Minocycline, 4-epioxytetracycline, 4-epitetracycline, tetracycline, demeclocycline, 4-epichlortetracycline, chlortetracycline, and methacycline were not detected. The developed method is simple to operate, highly sensitive, and can be used to precisely and accurately determine TCs. Accordingly, it is suitable for determining the abovementioned ten tetracycline antibiotics in animal muscle tissue.

Key words: tetracyclines (TCs), solid-phase extraction (SPE), ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), animal muscle tissue

中图分类号: