色谱 ›› 2015, Vol. 33 ›› Issue (6): 634-641.DOI: 10.3724/SP.J.1123.2015.02072

• 研究论文 • 上一篇    下一篇

Solidified floating organic drop microextraction combined with high performance liquid chromatography for the determination of carbamazepine in human plasma and urine samples

Mohammad ASADI1,2, Ali Mohammad HAJI SHABANI1, Shayessteh DADFARNIA1, Bijan ABBASI2   

  1. 1. Department of Chemistry, Faculty of Science, Yazd University, Yazd 89195-741, Iran;
    2. Khorassan Research Institute for Food Science and Technology, Mashhad 91851-76933, Iran
  • 收稿日期:2015-02-11 发布日期:2015-05-26
  • 通讯作者: Shayessteh DADFARNIA

Solidified floating organic drop microextraction combined with high performance liquid chromatography for the determination of carbamazepine in human plasma and urine samples

Mohammad ASADI1,2, Ali Mohammad HAJI SHABANI1, Shayessteh DADFARNIA1, Bijan ABBASI2   

  1. 1. Department of Chemistry, Faculty of Science, Yazd University, Yazd 89195-741, Iran;
    2. Khorassan Research Institute for Food Science and Technology, Mashhad 91851-76933, Iran
  • Received:2015-02-11 Published:2015-05-26

摘要:

Solidified floating organic drop microextraction (SFODME) in combination with high performance liquid chromatography was used for separation/preconcentration and determination of carbamazepine (CBZ) in human plasma and urine samples. Parameters that affect the extraction efficiency such as the type and volume of extraction solvent, ionic strength, sodium hydroxide concentration, stirring rate, sample volume and extraction time, were investigated and optimized. Under the optimum conditions (extraction solvent, 40 μL of 1-undecanol; sodium hydroxide concentration, 1 mol/L; temperature, 50 ℃; stirring speed, 400 r/min; sample volume, 8 mL; sodium chloride concentration, 3% (w/v) and extraction time, 60 min) the calibration curve was found to be linear in the mass concentration range of 0.4-700.0 μg/L. The limit of detection (LOD) was 0.1 μg/L and the relative standard deviation (RSD) for six replicate extraction and determination of carbamazepine at 100 μg/L level was found to be 4.1%. The method was successfully applied to the determination of CBZ in human plasma and urine samples.

关键词: carbamazepine (CBZ), high performance liquid chromatography (HPLC), plasma, preconcentration, solidified floating organic drop microextraction (SFODME), urine

Abstract:

Solidified floating organic drop microextraction (SFODME) in combination with high performance liquid chromatography was used for separation/preconcentration and determination of carbamazepine (CBZ) in human plasma and urine samples. Parameters that affect the extraction efficiency such as the type and volume of extraction solvent, ionic strength, sodium hydroxide concentration, stirring rate, sample volume and extraction time, were investigated and optimized. Under the optimum conditions (extraction solvent, 40 μL of 1-undecanol; sodium hydroxide concentration, 1 mol/L; temperature, 50 ℃; stirring speed, 400 r/min; sample volume, 8 mL; sodium chloride concentration, 3% (w/v) and extraction time, 60 min) the calibration curve was found to be linear in the mass concentration range of 0.4-700.0 μg/L. The limit of detection (LOD) was 0.1 μg/L and the relative standard deviation (RSD) for six replicate extraction and determination of carbamazepine at 100 μg/L level was found to be 4.1%. The method was successfully applied to the determination of CBZ in human plasma and urine samples.

Key words: carbamazepine (CBZ), high performance liquid chromatography (HPLC), plasma, preconcentration, solidified floating organic drop microextraction (SFODME), urine

中图分类号: