基于时间差异信号的移动界面电泳结合酶联免疫检测尿液中阿尔兹海默症相关神经丝蛋白

王迩骥, 刘伟文, 曹成喜, 张强*   

  1. 上海交通大学自动化与智能感知学院, 上海 200240
  • 收稿日期:2026-03-21
  • 基金资助:
    国家自然科学基金项目(22104082).

Time-difference signal-based detection of Alzheimers disease-associated neural thread protein in urine using moving boundary electrophoresis and enzyme-linked immunosorbent assay

WANG Erji, LIU Weiwen, CAO Chengxi, ZHANG Qiang*   

  1. School of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China
  • Received:2026-03-21
  • Supported by:
    National Natural Science Foundation of China (No.22104082).

摘要: 复杂体液中低丰度疾病生物标志物的精确定量对临床早期诊断具有重要意义。现有的基于移动反应界面(moving reaction boundary, MRB)与电泳滴定(electrophoretic titration, ET)理论的ET-酶联免疫吸附测定(enzyme-linked immunosorbent assay, ELISA)技术通过将生化信号转化为空间位移,实现了无需复杂光学仪器的床旁即时检测。在ET-ELISA的基础上,本研究提出了一种基于时间变量的分析策略,该方法根据双移动界面相遇时间的差异与检测样本的含量关系进行定量。本研究中蓝色TMB+界面与碱性界面对向迁移,以两界面相遇时间(tend)作为检测信号,将含量差异转化为时间信号差异。以阿尔茨海默病相关神经丝蛋白(Alzheimer-associated neuronal thread protein, AD7c-NTP)为模型的验证结果表明,基于时间-含量分析方法的线性范围为200~3β200 pg/mL,检出限为150 pg/mL,人工尿液中日内与日间相对标准偏差表现良好,日内平均回收率为99.7%,日间平均回收率为100.5%。对6例志愿者尿液样本的检测显示,其测定值与商业化ELISA试剂盒测定结果一致(相关系数r=0.987),证实了该策略可 用于复杂样本的定量分析。本研究将微小的含量差异转化为更易被捕捉的时间差异,在保留平台便携性的同时提升了检测灵敏度,为资源受限场景下的低丰度标志物即时检测与非侵入式疾病筛查提供了一种可靠的新策略。

关键词: 微芯片电泳, 电泳传感, 移动反应界面, 酶联免疫吸附, 生物标志物

Abstract: Accurate quantification of disease-related biomarkers in complex biofluids holds profound significance for early clinical diagnosis. Among biofluids, urine possesses unique advantages, including non-invasive collection and prolonged accumulation of early pathological products, making it a valuable medium for early disease screening and dynamic monitoring of disease progression. Recently, ET-ELISA (electrophoretic titration-enzyme-linked immunosorbent assay) technology, developed based on moving reaction boundary (MRB) and electrophoretic titration theories, successfully transforms immunochemical signals into measurable spatial distance. This approach effectively eliminates reliance on complex optical instruments, providing a robust platform for rapid bedside testing. However, when detecting low-abundance biomarkers, subtle variations in target concentration result in minimal boundary distance differences, imposing stringent requirements on the spatial resolution of conventional reading devices.
To address this challenge, this study proposes a time-domain quantification strategy that enables precise measurement of low-abundance disease biomarkers in urine. The study's contributions are twofold: the establishment of a time-difference-based quantification model and the validation of its analytical performance. First, extending traditional spatial quantification concepts, we continuously monitor the dynamic boundary migration within a simplified microchannel, bypassing the need for an additional redox boundary. Machine vision algorithms construct an inverted “V-shaped” distance-time profile to locate the intersection between the blue TMB+ (3,3',5,5'-tetramethylbenzidine cation) boundary and the colorless alkaline boundary. The time at this peak (tend) serves as the quantitative measure. This time-dependent sensing is governed by the asymmetric migration of background ions (K+ and Cl-) to maintain electroneutrality. The cathodic migration of positively charged TMB+ accelerates the reverse Cl- flux, inducing OH- generation and a reverse-migrating alkaline boundary. Elevated target concentrations yield more TMB+ which directly advances this alkaline boundary formation and shortens the meeting time. Visually, the blue TMB+ boundary turns yellow and reverses its migration direction earlier. Second, we validate the analytical performance of this quantitative system using the Alzheimer's disease-associated neural thread protein (AD7c-NTP) as a clinical model. Quantitative analysis of the boundary meeting time (tend) signal reveals a linear range of 200-3β200 pg/mL with an R2 of 0.985; the limit of detection (LOD) is 150 pg/mL. In artificial urine, the average intraday and interday recoveries are 99.7% and 100.5%, with relative standard deviations (RSDs) of 4.8% and 4.2%, respectively. Further application to 6 real human urine samples yielded results highly consistent with commercial ELISA kits (r=0.987), confirming the platform's accuracy and reliability in complex matrices.
The time-difference-based detection method exhibits the following advantages: (i) This strategy transforms the direct utilization of spatial distance into sequential time tracking of the peak point of the colored boundary's movement. The boundary meeting time (tend) serves as the readout parameter. This time-domain parameter converts subtle spatial variations into more distinguishable temporal signals, while preserving the suitability of the method for portable observation. (ii) This method achieves precise dynamic boundary tracking within a solution of more simplified composition, reducing the complexity of reagent preparation. (iii) The platform retains the advantage of classic ET-ELISA technology—requiring no large, specialized optical instruments, and the digital output format of boundary meeting time (tend) aligns with the developmental needs of high-precision, automated instruments. Together, these advantages support the application of this quantitative detection system for non-invasive disease screening and biochemical analysis in resource-limited settings.

Key words: microchip electrophoresis, electrophoretic sensing, moving reaction boundary (MRB), enzyme-linked immunosorbent assay (ELISA), biomarkers