Chinese Journal of Chromatography ›› 2012, Vol. 30 ›› Issue (11): 1108-1112.DOI: 10.3724/SP.J.1123.2012.08054

• Highlight • Previous Articles     Next Articles

Determination of capsaicinoids and eugenol in waste-edible-oil by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry

ZHANG Zhong*, REN Fei, ZHANG Pan   

  1. Material Evidence Identification Center of Chongqing Public Security Bureau, Chongqing 400021, China
  • Received:2012-08-28 Revised:2012-10-20 Online:2012-11-28 Published:2009-02-25

Abstract: A method was developed for the determination of capsaicinoids (capsaicin, dihydrocapsaicin and synthetic capsaicin) and eugenol in waste-edible-oil extracted by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The capsaicinoids and eugenol in waste-edible-oil were extracted by methanol, and then separated by a SUPEL COSIL ABZ+Plus dC18 column (150 mm×4.6 mm, 5 μm). The analysis was performed by MS/MS with electrospray ionization in positive and negative ion modes with multiple reaction monitoring (MRM). The limits of detection for capsaicin, dihydrocapsaicin, synthetic capsaicin and eugenol were 0.02, 0.03, 0.03 and 0.6 μg/L, respectively. The good linear relationships were obtained in certain concentration ranges of capsaicinoids and eugenol. The relative standard deviations (RSDs, n=5) of same-worker and different-worker were less than 5%. The method is exclusive, sensitive and accurate, and can be used in waste-edible-oil determination.

Key words: capsaicinoids, eugenol, waste-edible-oils, liquid chromatography-tandem mass spectrometry (LC-MS/MS)