Chinese Journal of Chromatography ›› 2016, Vol. 34 ›› Issue (7): 665-672.DOI: 10.3724/SP.J.1123.2015.11031

• Special Column on Progress of Aptamers Selection against Multiscale Targets • Previous Articles     Next Articles

Chemometric approach based on liquid chromatography- quadrupole/time of flight high resolution mass spectrometry to screen chemical hazards in infant formula

ZHANG Hongwei1, XU Hui1, ZHANG Xiaomei1, BAO Lei2, WANG Fengmei1, CHEN Liangzhen3, LIANG Chengzhu1, WANG Yanting1, QIN Liangyong1   

  1. 1. Technical Center of Inspection and Quarantine, Shandong Entry-Exit Inspection and Quarantine Bureau, Qingdao 266002, China;
    2. Nestlé Food Safety Institute, Beijing 100102, China;
    3. Qingdao Vland Biotech Group, Qingdao 266061, China
  • Received:2015-11-17 Online:2016-07-08 Published:2013-02-05
  • Supported by:

    Scientific and Technological Project of the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China (Nos. 2013IK176, 2014IK088);Scientific Research Project of Quality Inspection Service Industry (No. 201510036-01).

Abstract:

A chemometric model for screening chemical hazards in infant formula has been built based on liquid chromatography coupled to quadrupole/time of flight (Triple TOF®) mass spectrometry. Six chemicals, naming as salbutamol, lincomycin, sulfadiazine, spiramycin and megestrol acetate, were deliberately selected as the representatives of unknown chemical hazards to be spiked into infant formula. Fifteen different infant formula samples, with equal amount, were dissolved into water and mixed homogeneously to prepare test samples representing typical infant formula matrices. All test samples were divided into reference group (free from spiked chemicals) and spiked group. The test samples were extracted with acetonitrile, and then cleaned-up with Captiva NDLipids filtering solid phase extraction column. The liquid chromatographic separation was made on a CORTECSTM C18+column using mobile phases of 0.3%(v/v) formic acid-5%(v/v) water in acetonitrile and 0.3%(v/v) formic acid-5%(v/v) acetonitrile in water with gradient elution. Mass spectrometric analysis was conducted by a mixed acquisition mode of TOF full mass scan-information dependent acquisition (IDA)-product ion scan. Acquired data were exported to MarkerViewTM software (version 1.2.1.1, SCIEX, USA) for peak finding, alignment and filtering. Then the preprocessed data were subject to SIMCA-P software (version 14.0, Umetrics AB, Sweden) for discriminant analysis. An orthogonal partial least squares-discriminant analysis (OPLS-DA) model was built with good fitness and good prediction ability (R2X(cum)=0.742, R2Y(cum)=0.997, Q2Y(cum)=0.905). The reference and spiked samples were well grouped and the six chemicals (spiking level down to 50 μg/kg, based on weight of infant formula) were reliably identified by S-Plot of OPLS-DA model. The technological system for monitoring quality and safety of infant formula could be benefited from the proposed approach.

Key words: chemical hazards, chemometrics, infant formula, liquid chromatography-high resolution mass spectrometry, orthogonal partial least squares-discriminant analysis (OPLS-DA)

CLC Number: