Chinese Journal of Chromatography ›› 2018, Vol. 36 ›› Issue (3): 268-277.DOI: 10.3724/SP.J.1123.2017.11034

Previous Articles     Next Articles

Identification of the impurities in o-chlorophenyl cyclopentyl ketone samples by high performance liquid chromatography-hybrid ion trap/time-of-flight mass spectrometry and preparation of o-chlorophenyl cyclopentyl ketone standard

MA Xiaomeng1, JIN Lan1, LI Yaning1, ZHENG Hui2, WEI Yun1   

  1. 1. State Key Laboratory of Chemical Resource Engineering, Faculty of Sciences, Beijing University of Chemical Technology, Beijing 100029, China;
    2. Drug Detection Division, Institute of Forensic Science, Ministry of Public Security, Beijing 100038, China
  • Received:2017-11-21 Online:2018-03-08 Published:2018-04-04
  • Supported by:

    National Key Research and Development Program of China (No. 2017YFF0207800); National Natural Science Foundation of China (No. 21075007); Program for New Century Excellent Talents in University (No. NCET-11-0563); Beijing Nova Program Interdisciplinary Cooperation Project (No. Z161100004916045).

Abstract:

A method for the identification of relevant impurities in illegal o-chlorophenyl cyclopentyl ketone drug was developed. Identification of impurities could help regulation of this illegal drug and allow the sources of samples of the drug to be identified. An efficient and effective method for qualitatively analyzing samples using high performance liquid chromatography-hybrid ion trap/time-of-flight mass spectrometry (HPLC-IT/TOF MS) was developed. The o-chlorophenyl cyclopentyl ketone fragmentation pathway during HPLC-MSn was determined by analyzing a standard by HPLC-IT/TOF MS. The optimized HPLC-IT/TOF MS method allowed two impurities in o-chlorophenyl cyclopentyl ketone samples to be identified. According to the exact mass data of MSn and the element composition analysis, two impurities were identified as o-chlorobenzoic acid anhydride and 1,2-di-o-chlorobenzoylcyclopentene. The synthetic route of the o-chlorophenyl cyclopentyl ketone samples was proposed by analysis of these impurities. The established method made it easy to identify impurities and find the source of this illegal drug. A method for the preparation an o-chlorophenyl cyclopentyl ketone reference standard from actual samples using preparative HPLC was also developed. The mobile phase was methanol-water (85:15, v/v) and flow rate was 8 mL/min. The purity of the obtained standards, determined by analytical HPLC, was 99.53%. This method is simple, efficient, and can be used for the preparation of other illegal drugs.

Key words: o-chlorophenyl cyclopentyl ketone, high performance liquid chromatography-hybrid ion trap/time-of-flight mass spectrometry (HPLC-IT/TOF MS), impurity identification, preparative high performance liquid chromatography, standards

CLC Number: