Chinese Journal of Chromatography ›› 2026, Vol. 44 ›› Issue (11): 1367-1379.DOI: 10.3724/SP.J.1123.2026.01021
• Articles • Previous Articles Next Articles
ZHENG Junying, ZENG Hongyan, WU Xiaoping*(
)
Received:2026-03-12
Online:2026-11-08
Published:2026-11-03
Supported by:CLC Number:
ZHENG Junying, ZENG Hongyan, WU Xiaoping. Enrichment and analysis of trace microcystins in environmental water based on metal-organic framework HKUST-1 functionalized polymer monolithic column[J]. Chinese Journal of Chromatography, 2026, 44(11): 1367-1379.
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.chrom-china.com/EN/10.3724/SP.J.1123.2026.01021
| Analyte | Precursor ion (m/z) | Product ions (m/z) | Collision energies/eV |
|---|---|---|---|
| MC-RR | 519.9 | 135.1*,127.1 | 36,22 |
| MC-LRa | 498.4 | 135.1*,861.5 | 14,11 |
| MC-YRa | 523.4 | 135.1*,911.5 | 19,9 |
Table 1 MS/MS parameters of three microcystins (MCs)
| Analyte | Precursor ion (m/z) | Product ions (m/z) | Collision energies/eV |
|---|---|---|---|
| MC-RR | 519.9 | 135.1*,127.1 | 36,22 |
| MC-LRa | 498.4 | 135.1*,861.5 | 14,11 |
| MC-YRa | 523.4 | 135.1*,911.5 | 19,9 |
| Column | HKUST-1/mg | GMA/mg | AM/mg | DVB/mg | [HMIM][BF4]/mg | Cyclohexanol/mg | Permeability (K)/(10-14 m2) | SMC-LR |
|---|---|---|---|---|---|---|---|---|
| A | 0 | 24 | 16 | 60 | 60 | 40 | 15.3 | 207959 |
| B | 0 | 26 | 14 | 60 | 60 | 40 | 15.3 | 150628 |
| C | 0 | 22 | 18 | 60 | 60 | 40 | 7.66 | 171502 |
| D | 0 | 24 | 16 | 60 | 65 | 35 | 7.66 | 208332 |
| E | 0 | 24 | 16 | 60 | 55 | 45 | 15.3 | 219714 |
| F | 1 | 24 | 16 | 60 | 60 | 40 | 15.3 | 233172 |
| G | 3 | 24 | 16 | 60 | 60 | 40 | 7.66 | 240598 |
| H | 5 | 24 | 16 | 60 | 60 | 40 | 7.66 | 254036 |
| I | 7 | 24 | 16 | 60 | 60 | 40 | 3.83 | 198018 |
Table 2 Composition of the polymerization solution for the preparation of HKUST-1@poly(DVB-co-AM-co-GMA) monolithic column
| Column | HKUST-1/mg | GMA/mg | AM/mg | DVB/mg | [HMIM][BF4]/mg | Cyclohexanol/mg | Permeability (K)/(10-14 m2) | SMC-LR |
|---|---|---|---|---|---|---|---|---|
| A | 0 | 24 | 16 | 60 | 60 | 40 | 15.3 | 207959 |
| B | 0 | 26 | 14 | 60 | 60 | 40 | 15.3 | 150628 |
| C | 0 | 22 | 18 | 60 | 60 | 40 | 7.66 | 171502 |
| D | 0 | 24 | 16 | 60 | 65 | 35 | 7.66 | 208332 |
| E | 0 | 24 | 16 | 60 | 55 | 45 | 15.3 | 219714 |
| F | 1 | 24 | 16 | 60 | 60 | 40 | 15.3 | 233172 |
| G | 3 | 24 | 16 | 60 | 60 | 40 | 7.66 | 240598 |
| H | 5 | 24 | 16 | 60 | 60 | 40 | 7.66 | 254036 |
| I | 7 | 24 | 16 | 60 | 60 | 40 | 3.83 | 198018 |
Fig. 4 (a) N2 adsorption-desorption isotherm curves and (b) pore-size distribution of HKUST-1@poly(DVB-co-AM-co-GMA) functionalized monolithic material
Fig. 5 Effects of (a) pH of loading solution,(b) FA content in elution solution,(c) loading flow rate and (d) elution flow rate on extraction efficiencies of the three MCs (n=3)
Fig. 7 XPS spectra of (a) C 1s,(b) N 1s,(c) O 1s,(d) Cu 2p and (e) XPS full spectrum for HKUST-1@poly(DVB-co-AM-co-GMA) monolithic column before and after adsorption of MC-LR
| Analyte | Linear range/(μg/L) | R2 | LOD/(ng/L,S/N=3) | LOQ/(ng/L,S/N=10) | RSDs/% (n=5) | ||
|---|---|---|---|---|---|---|---|
| Column-to-column | Inter-day | Intra-day | |||||
| MC-LR | 0.01-10 | 0.9955 | 0.28 | 0.94 | 3.0 | 1.4 | 1.4 |
| MC-RR | 0.01-10 | 0.9986 | 0.60 | 1.99 | 2.6 | 2.3 | 3.4 |
| MC-YR | 0.01-10 | 0.9995 | 0.48 | 1.60 | 3.5 | 3.7 | 2.6 |
Table 3 Analytical performance of CME-LC-MS/MS method for MCs
| Analyte | Linear range/(μg/L) | R2 | LOD/(ng/L,S/N=3) | LOQ/(ng/L,S/N=10) | RSDs/% (n=5) | ||
|---|---|---|---|---|---|---|---|
| Column-to-column | Inter-day | Intra-day | |||||
| MC-LR | 0.01-10 | 0.9955 | 0.28 | 0.94 | 3.0 | 1.4 | 1.4 |
| MC-RR | 0.01-10 | 0.9986 | 0.60 | 1.99 | 2.6 | 2.3 | 3.4 |
| MC-YR | 0.01-10 | 0.9995 | 0.48 | 1.60 | 3.5 | 3.7 | 2.6 |
| Sample | Spiked/(μg/L) | MC-LR | MC-RR | MC-YR | |||||
|---|---|---|---|---|---|---|---|---|---|
| Detected/(μg/L) | Recovery (RSD)/% | Detected/(μg/L) | Recovery (RSD)/% | Detected/(μg/L) | Recovery (RSD)/% | ||||
| Reservoir water | 0 | 0.0027 | / | N.D. | / | N.D. | / | ||
| 0.05 | 0.041 | 82.2 (5.5) | 0.044 | 88.8 (3.0) | 0.056 | 111.0 (7.9) | |||
| 0.50 | 0.53 | 105.0 (2.5) | 0.56 | 112.0 (1.8) | 0.49 | 98.5 (1.7) | |||
| 5.0 | 5.5 | 111.1 (7.0) | 4.7 | 94.3 (2.3) | 5.2 | 103.0 (4.2) | |||
| River water | 0 | 0.0014 | / | 0.0023 | / | 0.0019 | / | ||
| 0.05 | 0.045 | 90.5 (4.3) | 0.052 | 104.0 (6.1) | 0.057 | 101.0 (1.4) | |||
| 0.50 | 0.55 | 109.0 (4.3) | 0.42 | 83.6 (5.8) | 0.45 | 90.9 (3.0) | |||
| 5.0 | 5.0 | 101.0 (3.7) | 4.6 | 93.2 (1.6) | 5.1 | 101.0 (2.4) | |||
| Lake water | 0 | 0.0012 | / | 0.0009 | / | N.D. | / | ||
| 0.05 | 0.048 | 95.3 (4.3) | 0.049 | 97.2 (4.7) | 0.50 | 100.0 (2.6) | |||
| 0.50 | 0.51 | 102.0 (2.8) | 0.42 | 83.2 (6.3) | 0.49 | 99.1 (2.0) | |||
| 5.0 | 4.8 | 96.4 (6.0) | 4.7 | 93.8 (1.7) | 5.2 | 104.0 (6.3) | |||
Table 4 Recoveries and precisions (RSDs) of the MCs with CME-LC-MS/MS method in three actual water samples (n=3)
| Sample | Spiked/(μg/L) | MC-LR | MC-RR | MC-YR | |||||
|---|---|---|---|---|---|---|---|---|---|
| Detected/(μg/L) | Recovery (RSD)/% | Detected/(μg/L) | Recovery (RSD)/% | Detected/(μg/L) | Recovery (RSD)/% | ||||
| Reservoir water | 0 | 0.0027 | / | N.D. | / | N.D. | / | ||
| 0.05 | 0.041 | 82.2 (5.5) | 0.044 | 88.8 (3.0) | 0.056 | 111.0 (7.9) | |||
| 0.50 | 0.53 | 105.0 (2.5) | 0.56 | 112.0 (1.8) | 0.49 | 98.5 (1.7) | |||
| 5.0 | 5.5 | 111.1 (7.0) | 4.7 | 94.3 (2.3) | 5.2 | 103.0 (4.2) | |||
| River water | 0 | 0.0014 | / | 0.0023 | / | 0.0019 | / | ||
| 0.05 | 0.045 | 90.5 (4.3) | 0.052 | 104.0 (6.1) | 0.057 | 101.0 (1.4) | |||
| 0.50 | 0.55 | 109.0 (4.3) | 0.42 | 83.6 (5.8) | 0.45 | 90.9 (3.0) | |||
| 5.0 | 5.0 | 101.0 (3.7) | 4.6 | 93.2 (1.6) | 5.1 | 101.0 (2.4) | |||
| Lake water | 0 | 0.0012 | / | 0.0009 | / | N.D. | / | ||
| 0.05 | 0.048 | 95.3 (4.3) | 0.049 | 97.2 (4.7) | 0.50 | 100.0 (2.6) | |||
| 0.50 | 0.51 | 102.0 (2.8) | 0.42 | 83.2 (6.3) | 0.49 | 99.1 (2.0) | |||
| 5.0 | 4.8 | 96.4 (6.0) | 4.7 | 93.8 (1.7) | 5.2 | 104.0 (6.3) | |||
| Method | Adsorbent | Samples | Sample consumption/mL | LODs/(ng/L) | Recoveries/% | Ref. |
|---|---|---|---|---|---|---|
| MSPE-LC-MS/MS | DS-MMIP@GO | tap water,river water | 1000 | 0.03-0.61 | 84.1-98.2 | [ |
| MSPE-HPLC-MS/MS | MCNTs@TpPa-1 | tap water | 20 | 0.8-1.5 | 85.0-106.0 | [ |
| SPME-LC-MS | aptamer@AuNPs@UiO-66-NH2 | lake water,tap water | 5 | 4 | 92.0-96.8 | [ |
| d-SPE-HPLC-MS | HFH-COF | biological samples | 20 | 0.6-0.8 | 85.7-108.7 | [ |
| SPE-LC-MS | Au-PPy nanocomposite sorbent | tap water | 2 | 1.5 | 94.1-103.2 | [ |
| CME-LC-MS/MS | HKUST-1@poly(DVB-co-AM-co-GMA) | lake water,tap water,reservoir water | 1 | 0.28-0.60 | 82.2-112.0 | this work |
Table 5 Comparison of the current strategy with previously reported methods for MCs analysis
| Method | Adsorbent | Samples | Sample consumption/mL | LODs/(ng/L) | Recoveries/% | Ref. |
|---|---|---|---|---|---|---|
| MSPE-LC-MS/MS | DS-MMIP@GO | tap water,river water | 1000 | 0.03-0.61 | 84.1-98.2 | [ |
| MSPE-HPLC-MS/MS | MCNTs@TpPa-1 | tap water | 20 | 0.8-1.5 | 85.0-106.0 | [ |
| SPME-LC-MS | aptamer@AuNPs@UiO-66-NH2 | lake water,tap water | 5 | 4 | 92.0-96.8 | [ |
| d-SPE-HPLC-MS | HFH-COF | biological samples | 20 | 0.6-0.8 | 85.7-108.7 | [ |
| SPE-LC-MS | Au-PPy nanocomposite sorbent | tap water | 2 | 1.5 | 94.1-103.2 | [ |
| CME-LC-MS/MS | HKUST-1@poly(DVB-co-AM-co-GMA) | lake water,tap water,reservoir water | 1 | 0.28-0.60 | 82.2-112.0 | this work |
|
| Viewed | ||||||
|