Chinese Journal of Chromatography ›› 2025, Vol. 43 ›› Issue (9): 1005-1013.DOI: 10.3724/SP.J.1123.2024.10002

• Articles • Previous Articles     Next Articles

Determination of 26 perfluorinated and polyfluoroalkyl compounds in human serum by solid-phase extraction-high performance liquid chromatography-tandem mass spectrometry

YUE Yingxiao1, BIAN Yating1, CHENG Yufan1, HE Lu1, WANG Dan1, YAN Peixia4, YAN Wei1,2,3, LIU Guiying1,2,3, SONG Huan1,2,3, LIU Liangpo1,2,3,*()   

  1. 1. Department of Public Health Laboratory Sciences,School of Public Health,Shanxi Medical University,Taiyuan 030001,China
    2. Key Laboratory of Coal Environmental Pathogenicity and Prevention,Ministry of Education,Shanxi Medical University,Taiyuan 030001,China
    3. Center for Ecological Public Health Security of Yellow River Basin,Shanxi Medical University,Taiyuan 030001,China
    4. Beijing Changping District Center for Disease Prevention and Control,Beijing 102200,China
  • Received:2024-10-08 Online:2025-09-08 Published:2025-09-04
  • Supported by:
    Shanxi Province Applied Basic Research Program(202203021221192);Doctor Start-up Fund from Shanxi Medical University(XD1915)

Abstract:

Perfluorinated and polyfluoroalkyl compounds (PFASs) represent a category of synthetic chemicals renowned for their environmental persistence. Owing to their hydrophobic, oleophobic, and high-temperature-resistant properties, PFASs are extensively utilized in industrial, agricultural, and civilian sectors, including applications in leather, textiles, flame-retardant materials, lubricants, and coatings, among others. PFASs can accumulate within the human body, exhibiting multi-organ toxicity. Continuous monitoring of PFASs with ambiguous toxicity profiles is vital for evaluating human exposure and associated health risks. Consequently, the establishment of a high-throughput and highly sensitive detection method is of paramount importance for accurately assessing the exposure levels of PFASs in the human body. In this study, a commercial high-throughput HMR-Lipid 96-well solid-phase extraction plate was adopted, combined with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), to establish a simple, efficient method that can simultaneously quantitatively detect 26 PFASs in human serum. Serum samples were extracted using the HMR-lipid 96-well solid-phase extraction plate. The Phenomenex C18 chromatography column (250 mm×4.6 mm, 5 μm) was used as the capture column and connected between the liquid chromatography mixer and the autosampler to avoid high background pollution. The target compounds were separated by the Accucore C18 chromatography column (100 mm×2.4 mm, 2.6 μm) and analyzed using the electrospray ionization with negative ion scanning mode and multiple reaction monitoring (MRM) mode. The methodological validation results indicated that the 26 PFASs had good linear relationships within the range of 0.2-100 ng/mL, with correlation coefficients (r) of 0.995 1-0.999 9. The limits of detection (LODs) and quantification (LOQs) were 0.01-0.15 ng/mL and 0.02-0.47 ng/mL, respectively. At three spiked levels of low, medium and high, the recoveries of the 26 PFASs ranged from 80.1% to 119.5%, and the relative standard deviations (RSDs) ranged from 0.5% to 11.9%. This method has the advantages of high sensitivity, good accuracy, simple operation, fast extraction speed, low reagent consumption and small sample volume required. It is suitable for large-scale population biological monitoring and provides a scientific method support for accurately assessing the exposure of PFASs in the human body and its potential health risks.

Key words: HMR-lipid 96-well solid-phase extraction plate, high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), perfluorinated and polyfluoroalkyl compounds (PFASs), human serum

CLC Number: